CVC Insertion Simulator II features three interchangeable pads for thorough experiential training:
- Transparent anatomical block to gain anatomical understanding in pre-training for catheterization
- Landmark puncture pad for teaching three methods of CVC approaches; a) Internal jugular; b) Subclavian vein; and c) Supraclavicular
- Ultrasound puncture pad for introductory training to acquire basics of ultrasound-guided puncture. Axillary vein and internal jugular vein approaches are available.
This modeloffers palpation, true-to-life needle tip resistance, success and failure confirmation, and cannultation with anatomically correct venous bifurcation.
Effective for cannulation training.The only simulator with anatomically correct junctions of the subclavian veins with the right internal jugular and SVC.Each training pad, placed at the right upper breast and right half of the neck covering the puncturing sites and catheter routes is a precise, life-size model incorporating the anatomical structure of bones, veins, arteries and upper lung.
Includes 3 interchangeable pads:
- Landmark Designed to provide training in safely puncturing the subclavian vein or internal jugular vein, and inserting a catheter into SVC. Carotid artery pulsation is palpable.
- Ultrasound Provides training in internal jugular vein puncturing under ultrasound scanning. Clear scanning image facilitates understanding of how to distinguish vein from artery and perform safe puncture while watching an ultrasound monitor.
- Transparent Proveds 3-dimensional anatomical understanding also works as an effective training tool for developing guide wire insertion skills.
The trainee will learn three skills: how to make a safer puncture, how to avoid possible complications that may accompany the puncture, how to insert the catheter into the correct position. When the procedure is performed incorrectly, the error will show immediately by feedback.
Three CVC approaches with landmark method:
- Subclavian vein approach
- Supraclavicular approach
- Internal jugular vein approach
Ultrasound guided CVC from internal jugular vein and axillary approach.
Complications indications:
– Artery puncture
-Pneumothorax
-Mislodging/malposition
Set includes:
1 male upper torso manikin
1 landmark puncture pad
1 ultrasound puncture pad
1 transparent anatomical block
1 introductory ultrasound training block
1 skin for cannulation training
1 red coloring powder
1 blue coloring powder
1 air bulb
2 plastic jars
1 irrigation bottle
1 syringe
1 sample needle
Manikin size: 40 x 41 x 21H cm, 2.2 kg (16″ x 16.5″ x 8.5″H, 5lbs.)
Packing size: 52 x 46 x 39 H cm, 9 kg (20.5″ x 18″ x 15.5″H, 20lbs.)
*Specifications are subject to change.
Manufacturer – Kyoto Kagaku M93UB, Item code: 11347-399